Home > Products > On Grid Solar Inverter > Residential Inverter > ES 4-10KT G3

ES 4-10KT G3

This series inverter is specially designed for three-phase PV systems, covering a wide power range of 4kW, 5kW, 6kW, 7kW, 8kW, 10kW. With compactness design, it is easy to install and operate. It supports wide AC output voltage to ensure longer working hour.
Product Description

 

· 2 MPP trackers, Max. efficiency up to 98.3% · Wide output voltage range
· Zero export application, VSG application · Anti-PID function (Optional)
· String intelligent monitoring (optional)  

 

  Datasheet  

Model ES4KT-G3 ES5KT-G3 ES6KT-G3 ES7KT-G3 ES8KT-G3 ES10KT-G3
Input Side
Max. DC Input Power (kW) 5.2 6.5 7.8 9.1 10.4 13
Max. DC Input Voltage (V) 1000
Start-up DC Input Voltage (V)  140
MPPT Operating Range (V) 120~850
Max. DC Input Current (A) 12.5+12.5
Number of MPPT / Strings per MPPT 2/1
Output Side
Rated Output Power (kW) 4 5 6 7 8 10
Max. Active Power (kW) 4.4 5.5 6.6 7.7 8.8 11
Rated AC Grid Voltage (V) 220 / 380, 230 / 400
AC Grid Voltage Range (V) 277Vac~460Vac (this may vary with grid standards)
Rated Grid Frequency (Hz) 50 / 60 (Optional)
Operating Phase Three phase
Rated AC Grid Output Current (A) 5.8 7.2 8,7 10.1 11.6 14.5
Max. AC Output Current (A) 6.4 8 9.6 11.1 12.8 15.9
Output Power Factor 0.8 leading to 0.8 lagging
Grid Current THD <3%
DC Injection Current (mA) <0.5%
Grid Frequency Range 47~52 or 57~62 (Optional)
Efficiency
Max. Efficiency 98.3%
Euro Efficiency 97.5%
MPPT Efficiency >99%
Protection
DC Reverse-Polarity Protection Yes
AC Short Circuit Protection Yes
AC Output Overcurrent Protection Yes
Output Overvoltage Protection Yes
Insulation Resistance Protection Yes
Ground Fault Monitoring Yes
Anti-islanding Protection Yes
Temperature Protection Yes
Integrated DC Switch Yes
Remote software upload Yes
Remote change of operating parameters Yes
Surge protection DC Type II / AC Type II 
General Data
Size (mm) 330W×430H×177D
Weight (kg) 15
Topology Transformerless
Internal Consumption <1W (Night)
Running Temperature -25~65℃
Ingress Protection IP65
Noise Emission (Typical) <25 dB
Cooling Concept Natural cooling
Max. Operating Altitude Without Derating 2000m
Designed Lifetime >20 years
Grid Connection Standard EN50549-1, IEC61727, IEC62116, IEC60068, IEC61683, VDE 0126-1-1, RD1699, UNE 206006 IN, UNE 206007-1 IN, UNE 217001 IN
Operating Surroundings Humidity 0-100%
Safety EMC / Standard IEC62109-1/-2, IEC61000-6-1, IEC61000-6-3, IEC61000-3-2, IEC61000-6-3, IEC61000-3-11, IEC61000-3-12
Features
DC Connection MC-4 mateable
AC Connection IP65 rated plug
Display LCD1602
Interface RS485/RS232/Wifi/LAN

Request a Quote

Chat with Us