· MPP tracker, Max. efficiency up to 97.7% | · Wide output voltage range |
· Anti-PID function (Optional) | · Zero export application, VSG application |
· String intelligent monitoring (optional) | · Low start-up voltage of 80V |
Datasheet
Model | ES9KS-G1 | ES10KS-G1 | ES10K5S-G1 |
Input Side | |||
Max. DC Input Power (kW) | 11.7 | 13 | 13.7 |
Max. DC Input Voltage (V) | 550 | ||
Start-up DC Input Voltage (V) | 80 | ||
MPPT Operating Range (V) | 70~550 | ||
Max. DC Input Current (A) | 25+25 | ||
Number of MPPT / Strings per MPPT | 2/2 | ||
Output Side | |||
Rated Output Power (kW) | 9 | 10 | 10.5 |
Max. Active Power (kW) | 9.9 | 11 | 11.6 |
Rated AC Grid Voltage (V) | 220/230(Optional) | ||
AC Grid Voltage Range (V) | 160 Vac~300 Vac (this may vary with grid standards) | ||
Rated Grid Frequency (Hz) | 50 / 60 (Optional) | ||
Operating Phase | Single phase | ||
Rated AC Grid Output Current (A) | 39.1 | 43.5 | 45.7 |
Max. AC Output Current (A) | 43 | 47.8 | 50.2 |
Output Power Factor | 0.8 leading to 0.8 lagging | ||
Grid Current THD | <3% | ||
DC Injection Current (mA) | <0.5% | ||
Grid Frequency Range | 47~52 or 57~62 (Optional) | ||
Efficiency | |||
Max. Efficiency | 97.7% | ||
Euro Efficiency | 97.5% | ||
MPPT Efficiency | >99% | ||
Protection | |||
DC Reverse-Polarity Protection | Yes | ||
AC Short Circuit Protection | Yes | ||
AC Output Overcurrent Protection | Yes | ||
Output Overvoltage Protection | Yes | ||
Insulation Resistance Protection | Yes | ||
Ground Fault Monitoring | Yes | ||
Anti-islanding Protection | Yes | ||
Temperature Protection | Yes | ||
Integrated DC Switch | Yes | ||
Remote software upload | Yes | ||
Remote change of operating parameters | Yes | ||
Surge protection | DC Type II / AC Type II | ||
General Data | |||
Size (mm) | 330W×410H×198.5D | ||
Weight (kg) | 15.7 | ||
Topology | Transformerless | ||
Internal Consumption | <1W (Night) | ||
Running Temperature | -25~65℃ | ||
Ingress Protection | IP65 | ||
Noise Emission (Typical) | <25 dB | ||
Cooling Concept | Natural cooling | ||
Max. Operating Altitude Without Derating | 2000m | ||
Designed Lifetime | >20 years | ||
Grid Connection Standard | ABNT NBR 16149, ABNT NBR 16150, ABNT NBR IEC 62116 | ||
Operating Surroundings Humidity | 0-100% | ||
Safety EMC / Standard | EC61000-6-1, IEC61000-6-3, IEC61000-3-11, IEC61000-3-12 | ||
Features | |||
DC Connection | MC-4 mateable | ||
AC Connection | IP65 rated plug | ||
Display | LCD1602 | ||
Interface | RS485/RS232/Wifi/LAN |